イベント情報詳細 |
||
2012.08.15 公開 | ||
【展示会】 第19回国際質量分析会議 IMSC2012[ 展示 ]
会期:9月16日(日)〜20日(木) 会場:国立京都国際会館 展示ルーム:Room C-1 NO.48
|
||
|
||
|
||
IonSense/AMR ランチョンセミナー |
||
|
||
Moderator: Yasuhiko Bando (AMR, Inc.)
1. DART-MS Strategies for Rapid Screening and Quantitation of Pesticides Elizabeth Crawford (IonSense, Inc.) Pesticides and fungicides can be detected rapidly by using DART-MS. The capability for screening and quantitation of residues in order to efficiently monitor produce products before reaching the consumer market is the topic of this presentation. The Direct Analysis in Real Time (DART) ambient ionization technique offers the ability to rapidly screen the surface of produce for pesticides by a direct swabbing method and permits direct analysis of fruit juices in seconds. With automated sample introduction rapid screening and quantitative measurements can be completed using DART ionization coupled to high resolution accurate mass and triple quadrupole mass spectrometers.
2. OpenSpot® Mass Spectrometry tools for Real-Time Quality Assessment using DART ionization sources Brian Musselman (IonSense, Inc.) The rapid sampling of DART-MS permits monitoring of reaction products in seconds per sample using only a few microliters of sample. A rapid desorption system that allows for both detection of the acids by negative ion detection of the deprotonated molecule. The utility of this method for quality control experiments will be discussed using determination of fatty acids from edible oil. In these experiments the mesh is attached to a variable-current power supply that can deliver sufficient current to heat the sample at a rate > 20X faster than the conventional DART cartridge heater.As monitoring of the production of fatty acids is completed in seconds per sample the method shows promise as a tool for detection of low and moderate levels of contaminants, monitoring the progress of biofuel production, detection of adulterants and non-specific threats.
3. Advantages of Using DART Ionization with Different Types of Mass Specs Teruhisa Shiota (AMR, Inc.) Various examples of DART-MS analysis will be presented to illustrate the advantages of using the Direct Analysis in Real Time ionization method with different types of mass spectrometers such as single/triple quadrupole and Orbitrap. The new DART ID CUBE features more powerful heating mechanism to allow analyses of metal organic complexes and pigments that were difficult to analyze with the conventional DART ionization sources.
|
||
ポスター発表 |
||
1.Quantitative Analysis of Carbendazim in Orange Juices by Direct Analysis in Real Time(DART) Mass Spectorometory |
||
|
||
![]() |